BSWHJ - GACOFLEX N-1239 ACCELERATOR

  • MSDS: BSWHJ
  • Manufacturer: GACO WESTERN INC
  • Product Name: GACOFLEX N-1239 ACCELERATOR
  • National Stock Number: 8010-00N041774
Product Identification

Product ID:GACOFLEX N-1239 ACCELERATOR
MSDS Date:01/01/1989
FSC:8010
NIIN:00N041774
MSDS Number: BSWHJ

Responsible Party
GACO WESTERN INC
18700 S CENTER PARKWAY
TUKWILA, WA 98188
US

Emergency Phone: 206-575-0450

Info Phone: 206-575-0450

Cage: 09463

Contractor
GACO WESTERN INC
88698 SEATTLE, WA 98188-4636 US

Telephone: 206-575-0450

Cage: 09463

Ingredients

LEAD MONOXIDE; (LEAD OXIDE)

CAS: 1317-36-8

RTECS: OG1750000

Fraction By Weight: 56%

OSHA PEL 0.05 MG/M3 (PB)

ACGIH TLV: 0.15 MG/M3 (PB)


6

CAS: 1330-20-7

RTECS: ZE2100000

Fraction By Weight: 35%

OSHA PEL 100 PPM;150 PPM STEL

ACGIH TLV: 100 PPM;150 PPM STEL

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


BUTYRALDEHYDE-ANALINE;

CAS: 34562-31-7

Fraction By Weight: 9%

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: INHALATION OF HIGH
CONCENTRATION CAN PRODUCE CENTRAL NERVOUS DEPRESSION. SKIN CONTACT
CAN CAUSE SEVERE IRRITATION, POSSIBLE BURNS, DEFATTING &
DERMATITIS. EYE CONT CAUSES SEVERE IRRITATION, RED NESS, TEARING &
BLURRED VISION. INGEST MAY CAUSE LIVER &/OR KIDNEY DAMAGE. LEAD
OXIDE IS POISONOUS. (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ: SYMPS MAY INCLUDE TIREDNESS, LOSS OF
APPETITE, STOMACH CRAMPS, MUSCLE WEAKNESS, CONVULSIONS & DEATH.
LEAD COMPOUNDS APPEAR ON THE NAVY LISTING OF OCCUPATIONAL
REPRODUCTIVE CHEMICAL REPRODUCT IVE HAZARDS. CONSULT APPROPRIATE
HEALTHPROFESSIONALS ABOUT LATEST HAZARD LIST INFO & SAFE HANDLING &
EXPOS INFO .
Medical Cond Aggravated by Exposure:RPTD EXPOS CAN CAUSE ALLERGIC RXN
W/DEVEL OF OCCUP ASTHMA. LONG TERM EXPOSURE TO LOW VAPOR
CONCENTRATIONS MAY CAUSE CHRONICALLY PROGRESSIVE PULMONARY DISEASE.
RPTD SKIN CONT CAN RSLT IN SENSIT.

First Aid

First Aid:INHAL: REMOVE TO FRESH AIR & IF BREATHING HAS STOPPED, GIVE
ARTIFICIAL RESPIRATION. EYE: FLUSH IMMED WITH WATER FOR AT LEAST 15
MINUTES & CALL A PHYSICIAN AS SOON AS POSSIBLE. SKIN: WASH WITH
SOAP AND WATER AND REMOVE CONTAM CLTHG. INGEST:SEE A PHYSICIAN AS
SOON AS POSSIBLE.

Fire Fighting

Flash Point Method:TCC
Flash Point:80F,26.7C
Lower Limits:1%
Extinguishing Media:FOAM, CARBON DIOXIDE, DRY CHEMICAL OR WATER FOG.
Fire Fighting Procedures:NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP. COOL
CONTRS W/WATER FOG TO PVNT RUPTURE. BOILOVER MAY OCCUR WHEN TEMP OF
MATL APPROACHES BOILING PT (SUPP DATA)
Unusual Fire/Explosion Hazard:SPILLS/VAP LEAKS READILY FROM FLAMM MIXT
@/ABOVE FL PT. IT IS UNLIKELY THAT THIS PROD WILL EXPLODE DUE TO
MECH IMPACT BUT FIRE/EXPLO MAY OCCUR FROM (SUPP DATA)

Accidental Release

Spill Release Procedures:REMOVE ALL SOURCES OF IGNITION. IN ENCLOSED
AREAS, CLEANUP PERSONNEL SHOULD WEAR NIOSH/MSHA APPROVED SCBA.
COVER SPILLS WITH ABSORBENT MATERIAL AND COLLECT WITH NON-SPARKING
TOOLS.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:KEEP CONTAINERS CLOSED AND STORE IN A
COOL DRY PLACE W/ADEQ EXPLO PROOF VENT. KEEP AWAY FROM HEAT, SPARKS
& OPEN FLAME.
Other Precautions:GROUND EQUIPMENT TO PREVENT ACCUMULATION OF STATIC
CHARGE.

Exposure Controls

Respiratory Protection:USE NIOSH/MSHA APPROVED ORGANIC VAPOR CARTRIDGES
WITH A MECHANICAL FILTER TO REMOVE AIRBORNE PARTICLES AND VAPORS.
USE NIOSH/MSHA APPROVED SCBA IN ENCLOSED AREAS INVOLVING HIGHER
CONCENTRATIONS.
Ventilation:LOC EXHAUST/MECHANICAL: EXPLO PROOF MECH EQUIPMENT CAPABLE
OF KEEPING VAPOR CONCENTRATION BELOW TLV.
Protective Gloves:CHEMICAL RESISTANT PLASTIC/RUBBER.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:EYE BATH AND SAFETY SHOWER SHOULD BE
AVAILABLE.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
FIRE FIGHT PROC: OF SOLV. DO NOT EXTING FLAME @ LEAK BECAUSE
POSSIBILITY OF UNCONTROLLED EXPLOS REIGNIT EXISTS. CUT OFF FUEL
&/OR ALLOW FIRE TO BURN OUT. EXTING SM RESIDUAL FIRES W/CHEM
POWDER/FOAM. E XPLO HAZ: STATIC ACCUMULATION AND DISCHARGE.

Chemical Properties

Boiling Pt:B.P. Text:>100F,>38C
Vapor Pres:SEE INGRED
Vapor Density:HVR/AIR
Spec Gravity:1.797
Evaporation Rate & Reference:SLOWER (ETHER=1)
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume:74

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING MATERIALS LIKE LIQUID CHLORINE AND CONCENTRATED
OXYGEN.
Stability Condition to Avoid:HEAT, SPARKS AND OPEN FLAME.
Hazardous Decomposition Products:INCOMPLETE COMBUSTION MAY PRODUCE
OXIDES OF LEAD, CARBON MONOXIDE &/OR CARBON DIOXIDE.

Disposal

Waste Disposal Methods:DISPOSE IN ACCORDANCE WITH LOCAL, STATE, AND
FEDERAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.